The purpose of this certificate course is to provide an intensive review of the ANSI/IIAR 2-2021 “American National Standard for Safe Design of Closed-Circuit Ammonia Refrigeration Systems,” and in the process expose learners to best practices in the proper design and safe operation of industrial refrigeration systems.
Because
the ANSI/IIAR 2 standard establishes minimum safe design criteria for
closed-circuit ammonia refrigeration systems, this course is relevant
for end users, facility managers, engineers, designers, design/build
contractors, regulators, and PSM/safety specialists.
Topics covered during the eight sessions include: system design requirements; machinery room requirements; electrical safety; ammonia detection and alarm; ventilation; signage; requirements for non-machinery room spaces; equipment; piping; and overpressure protection devices. Throughout the course curriculum, there is a focus on the connection between the design of a refrigeration system; appropriate inspection, testing, and maintenance tasks; and process safety management. The safety focus extends to persons and property located at or near the premises where refrigeration systems are located.
After participating in this activity, learners will be able to :
* Demonstrate the relationship between proper design of a closed-circuit ammonia refrigeration system and safe, efficient operation of that system
* Describe appropriate and safe location of ammonia refrigeration equipment and outline general design requirements for construction of closed-circuit ammonia refrigeration systems
* Discuss design and installation considerations for machinery rooms and requirements for refrigeration equipment located in areas other than machinery rooms
* Understand safe installation and proper operation of equipment that may be employed in closed-circuit ammonia refrigeration systems, including compressors, refrigerant pumps, condensers, evaporators, pressure vessels, piping, packaged systems and equipment, overpressure protection devices, instrumentation and controls, and ammonia detectors and alarms
IIAR 2-2021 Certificate Course Agenda
Module 1
· Introduction
· Chapter 1 - Purpose, Scope, and Applicability
· Chapter 2 - Definitions
· Chapter 3 - Reference Standards
Module 2
· Chapter 4 - Location of Ammonia Refrigeration Machinery
· Chapter 5 - General System Design Requirements
· Appendix A - Explanatory Material
Module 3
· Chapter 6 - Machinery Rooms
· Chapter 7 - Refrigeration Equipment Located in Areas Other Than Machinery Rooms
· Appendix A - Explanatory Material
Module 4
· Chapter 8 - Compressors
· Chapter 9 - Refrigerant Pumps
· Chapter 10 - Condensers
· Appendix A - Explanatory Material
Module 5
· Chapter 11 - Evaporators
· Chapter 12 - Pressure Vessels
· Chapter 13 - Piping
· Appendix A - Explanatory Material
Module 6
· Chapter 14 - Packaged Systems and Equipment
· Chapter 15 - Overpressure Protection Devices
· Chapter 16 - Instrumentation and Controls
· Chapter 17 - Ammonia Detection and Alarms
· Chapter 18 - Absorption Refrigeration
· Appendix A - Explanatory Material
Module 7
· Appendix A - Explanatory Material
· Appendix B - Ammonia Characteristics and Properties
· Appendix C - Methods for Calculating Relief Valve Capacity for Heat Exchanger Internal Loads
· Appendix D - Duplicate Nameplates on Pressure Vessels
· Appendix E - Method for Calculating Discharge Capacity of a Positive Displacement Compressor Pressure Relief Device
· Appendix F - Pipe Hanger Spacing, Hanger Rod Sizing, and Loading
· Appendix G - Hydrostatic Overpressure Relief
Module 8
· Appendix H - Stress Corrosion Cracking
· Appendix I - Emergency Pressure Control System
· Appendix J - Machine Room Signs
· Appendix K - Alternative Ventilation Calculation Methods
· Appendix L - Pipe, Fittings, Flanges, and Bolting
· Appendix M - Operational Containment
· Appendix N - Ammonia Absorption Refrigeration
· Appendix O - Designing to Avoid Component Failure Caused by Abnormal Pressure or Shock
· Appendix P - Removal of Water from a System
· Appendix Q - Guidelines for the Identification of Ammonia Refrigeration Piping and Equipment System Components
· Appendix R - References and Sources of References